91+ 8919121300

admin@renovatebio.com

Lifeport Kidney transporter 1.1

LIFEPORT KIDNEY TRANSPORTER

The Clinical Need in Renal Transplantation

The innovative LifePort technology has proven to significantly improve 1-year and 3-year graft survival for all types of deceased donor kidneys when compared with cold static storage.1,2

LifePort Kidney Transporter provides a sealed, sterile environment where a specially formulated physiologic solution is gently pumped through the kidney at cold temperatures to minimize tissue damage while the organ is being preserved outside the body. LifePort Kidney Transporter is lightweight and portable allowing an organ to be perfused from time of recovery until transplantation. It is designed to travel unaccompanied by land or air, safely transporting the kidney across town or between countries. While the kidney is being perfused, LifePort Kidney Transporter records data on temperature, flow rate, vascular resistance and pressure every 10 seconds, offering clinicians important additional data.

Long-term survival of kidney grafts is not improving despite better donor management and improved immunosuppression.1 The number of people needing dialysis for end-stage renal failure is likely to double in the next 10 years.2

Finding ways to help bridge the gap between demand and supply of organs is vital
Transforming Outcomes with LifePort Kidney Transporter

Combining innovative technology, user-friendly design and an advanced technology platform, LifePort Kidney Transporter has revolutionized kidney preservation. Compelling evidence shows that LifePort can improve the odds of a good outcome.

Both 1-year and 3-year graft survival for all Deceased Donor Kidneys (DCD) is better with LifePort Kidney Transporter when compared with cold static storage.3,4

Delayed Graft Function (DGF): the clinical challenge

Graft survival in kidney transplantation is strongly impacted by the occurrence of DGF, particularly in kidneys from marginal donors.

Impact of Delayed Graft Function
  • Negative impact on long-term graft survival
  • Increased risk of acute rejection
  • Increased healthcare costs6
  • Poor outcomes for the patient6
  • Transforming outcomes, transforming lives

    LifePort Kidney Transporter helps surgeons transplant kidneys with confidence, even kidneys considered to be from marginal donors. State-of-the-art preservation with LifePort has proven to significantly reduce the risk of DGF for all kidney donor types compared with cold static storage.

    Routinely protecting and preserving expanded criteria donor (ECD) kidneys and DCD kidneys with LifePort Kidney Transporter could make all the difference.

    Transforming knowledge: improving decision making

    The fully portable LifePort Kidney Transporter captures and displays key performance data in real time.

    Onboard digital readouts show patient ID number, blood type, temperature, diastolic and systolic pressure, flow, resistance and perfusion time.

    The on-board GPS/GPRS system offers capability for routine transmission of location and key performance data. Perfusion related data is available for rapid download via USB port.

    Custom-Made for Kidney Perfusion

    The self-contained Perfusion Circuit cradles the organ in cold physiologic solution. A custom-made disposable cannula, comfortably supported by an adjustable mount, allows swift connection of the kidney to LifePort Kidney Transporter, even for organs with the most challenging anatomies. And the entire disposable apparatus set – complete with organ cassette, pressure sensor and preservation solution – loads and unloads in one easy motion.

    Innovative design – LifePort Kidney Transporter Cover

    Designed to assist in transportation of LifePort Kidney Transporter, optional Biological Substance Category B (UN 3373) clinical samples, and provide donor/organ documentation storage.

  • Developed in collaboration with industry to address recent European Union directives aimed at ensuring the safety and quality of organs intended for transplantation
  • Facilitates unattended shipping of LifePorted kidneys and relevant biological samples
  • Designed to add increased protection for LifePort Kidney Transporter 1.1
  • Allows LifePort Kidney Transporter's digital display screen to be fully visible
  • Provides convenient compartment for documents
  • Accommodates ready securing of zip ties to prevent tampering
  • Easy maneuverability with telescopic pull handle; steerable wheels with lock-ability
  • Optional sealable Biological Substance Category B (UN 3373) compartment
  • Clinical Evidence Supports the Use of LifePort Kidney Transporter

    The Machine Preservation Trial, an international prospective randomized controlled clinical trial to investigate the incidence and risk of delayed graft function (DGF) in kidneys preserved by machine perfusion prior to transplantation, demonstrated that machine perfusion with LifePort Kidney Transporter significantly reduces all types of deceased donor kidneys.

    Our complete organ transplant container system includes:
  • Perfusion Circuit to contain the kidney and perfusate under asepticconditions during transport
  • Custom-made cannulas for secure connection to any kidney vasculature
  • Sterile Drape to maintain aseptic conditions while working inside thePerfusion Circuit
  • Preservation Solutions to maintain organ viability during preservation
  • Our complete organ transplant container system includes:

    Transporting a donated kidney safely is your highest priority.

    Physical protections include:
  • Ultrasonic bubble detectors to prevent air from entering the vasculature
  • Static cold storage backup for ultimate safety
  • Surrounded by physiologic solution in Perfusion Circuit
  • Pressure-controlled pump letting you set the pressure based on kidneyvasculature
  • Gentle flow increases during vasodilation to avoid barotrauma
  • Built for Movement

    When life is on the line, you need to move fast. Our LifePort Kidney Transporter is designed to be easy-to-use for ultimate transportability.

    Features include:
  • Designed to pump OR to OR
  • Can pump end-ischemically if transportation is not available
  • Only 45 pounds (20.4 kg) fully loaded to allow for one person lift
  • Eliminates the need for separate cold storage
  • ENQUIRY FORM

    Complete this Enquiry Form to obtain additional information about our services or send personal complaints. We will analyze your enquiry and return to you shortly by email or phone.